Nine Star–How to protect bearings - Linqing Nine Star Bearing Science & Technology Co.,Ltd
Your are here: HomeNewsContent
News

Nine Star–How to protect bearings

2015-07-20

For electrically insulated bearings from Nine Star, the insulating layer is applied to the outer ring or the
inner ring by plasma-spraying, a thinfilm technology. During plasma- spraying, an electric arc is created between
two electrodes with a suitable gas supply. The plasma jet serves as a carrier medium for applying the aluminium
oxide powder either to the outer or inner ring at high velocity. In order to obtain optimum protection the oxide
layer also covers the side faces of the sprayed rings. In the next process step, the layer is then sealed to prevent
any penetration by moisture.

 

The physical effect of the insulation layer depends on the frequency of the voltage that causes the harmful
currents in the bearings. In the case of DC voltage, the insulated bearing has Ohmic resistance. The higher this
resistance is, the lower the electrical current. The resistance value of the insulated bearings is greater than 50
MΩ, thus limiting the electrical current to a level that cannot cause damage to the bearing.